EATON
Eaton 9395XC UPS – High Efficiency, Scalable Power Protection
Eaton 9395XC UPS – High Efficiency, Scalable Power Protection
Couldn't load pickup availability
The Eaton 9395XC UPS is engineered to handle the growing power demands of modern data centers and mission-critical facilities. Delivering the highest power density with the smallest footprint in its class, this monolithic UPS system ensures dependable, flexible, and future-ready power protection.
Whether deployed in hyperscale data centers, colocation facilities, enterprise IT environments, or light industrial applications, the Eaton 9395XC UPS provides unmatched scalability and reliability. Supporting both VRLA and lithium-ion batteries, it offers power ratings from 1125 to 2250 kW.
With Eaton’s Energy Saver System (ESS), the 9395XC UPS achieves up to 99% efficiency, significantly reducing operating costs while maintaining robust protection.
Key Benefits of the Eaton 9395XC UPS
Compact Footprint – More Space for IT Equipment
-
Industry-leading power density (kW/ft²) for maximum efficiency.
-
Silicon carbide technology reduces footprint by up to 50%, optimizing data center floor space.
-
Flexible installation options as a stand-alone UPS or integrated with switchgear.
-
Supports prefabricated power solutions for easier deployment and optimized layouts.
Simplified Deployment & Commissioning
-
Short lead times enabled by world-class manufacturing processes.
-
Self-diagnostic software and service tool integration minimize commissioning time.
-
Easy Capacity Test eliminates costly load bank rentals and reduces burn-in testing expenses.
-
Backed by Eaton’s global service and support network.
Proven Reliability & Resiliency
-
HotSync® patented load-sharing technology eliminates single points of failure.
-
ESS mode provides transient suppression without sacrificing efficiency.
-
Handles up to 0.7 leading or lagging load power factors with no derating.
-
Seamless integration with Eaton Brightlayer™ Data Centers suite for real-time monitoring and power infrastructure management.
Why Choose the Eaton 9395XC UPS?
-
Best-in-class efficiency: Up to 99% in Energy Saver Mode.
-
Future-ready flexibility: Supports both VRLA and lithium-ion battery systems.
-
Scalable power: 1125 – 2250 kW to meet expanding power requirements.
-
Global support: Backed by Eaton’s worldwide service and maintenance network.
FAQs – Eaton 9395XC UPS
Q1: What makes the Eaton 9395XC UPS different from other UPS systems?
The 9395XC offers the highest power density per square foot, reducing the overall system footprint by up to 50% while achieving up to 99% efficiency with Eaton’s Energy Saver System.
Q2: Does the Eaton 9395XC support lithium-ion batteries?
Yes. The 9395XC UPS supports both VRLA and lithium-ion batteries, giving businesses flexibility in energy storage and long-term cost savings.
Q3: What industries typically use the 9395XC UPS?
The system is designed for hyperscale and colocation data centers, enterprise IT environments, healthcare facilities, and light industrial applications requiring uninterrupted, reliable power.
Q4: What is the power capacity of the Eaton 9395XC?
It offers a scalable power range of 1125 kW to 2250 kW, making it suitable for growing data center and industrial workloads.
Q5: How does the Eaton 9395XC UPS improve data center efficiency?
With silicon carbide technology and Energy Saver Mode, it maximizes efficiency, reduces heat output, and lowers total cost of ownership—all while providing uncompromising protection.
Eaton 9395XC UPS technical specifications
| UPS rating (unity power factor 1.0) | |
| kW/kVA |
1125/1125 1500/1500 2250/2250 |
| Efficiency | 99% in Energy Saver System (ESS) (up to 97.5% efficiency (480V) in double-conversion) |
| Parallel capability | 2 UPS units maximum (3 MW) |
| Audible noise |
67dBA @ 1 meter (50% load) 73dBA @ 1 meter (100% load) |
| Altitude (max) | 1000m at 40 degree C (104 degree F) |
| Input characteristics | |
| Voltage | 480V 3W |
| Voltage range | +10% / -15% |
| Frequency range | 45–65 Hz |
| Power factor | 0.99 for output loads greater than 60% |
| Input current distortion | <3% (no input filter required) |
| Soft start capability | Yes |
| Output characteristics | |
| Voltage | 480V 3W |
| Regulation | ±1% |
| Inverter | PWM |
| Voltage THD | <1% (100% linear load); <5% (non-linear load) |
| Load power factor range | Up to a 0.7 power factor leading/lagging without derating Up to a 0.5 power factor lagging with derating |
| Overload | 110% for 10 min; 125% for 120 sec; 150% for 10 sec; >150% for 300 msec (UPS transfer to bypass after overload time expires) |
| Battery | |
| Battery types | VRLA, AGM, wet cell, lithium-ion |
| Battery voltage | 480V |
| Charging method | ABM technology or float, selectable |
| Dimensions (480V system) | |
| 1125 kW / 1125 kVA | 93.5” w x 33.5” d x 78.9” h |
| 1500 kW / 1500 kVA | 106.3” w x 33.5” d x 78.9” h |
| 2250 kW / 2250 kVA | 186.4” w x 33.6” d x 78.9” h |
| General characteristics | |
| Control panel | Color touchscreen interface |
| Battery startup | Standard |
| Frequency conversion | Standard |
| Multi-language | Standard |
| Building alarm inputs | 5 (galvanic isolated) |
| Individual fan fail monitoring | Included |
| Power Semiconductor Temperature Monitoring | Included |
| Options | External maintenance bypass PDU, RPP and STS Maintenance bypass module, 2/3/4 breaker DC disconnects Human Machine Interface (HMI) designs for monitoring of connected equipment |
| PredictPulse remote monitoring and management service | PredictPulse is the industry’s first cloud-based 24x7 remote monitoring and predictive analytics subscription service to forecast data center power component failure and proactively replace components before failure. PredictPulse is included with the 9395XC UPS for the first year at no-charge along with the Eaton Environmental Monitoring Probe Gen 2 (customer self-installs via outbound email server or optional 4G/LTE wireless modem). |
| Communications |
Direct battery monitoring via Modbus TCP/IP from UPS Ethernet port Software compatibility: Software and Power Xpert Reporting |